Switch on/ off is actually magnetic flout contact open/ close after magnetron bistable exciting.Alarm sound and light are based on the switch position of on/ off linked to relays among other parts and elements.
Switch on/ off is actually magnetic flout contact open/ close after magnetron bistable exciting.Alarm sound and light are based on the switch position of on/ off linked to relays among other parts and elements.
■Introduce
1) Philosophy
2) Switch on/ off is actually magnetic flout contact open/ close after magnetron bistable exciting.Alarm sound and light are based on the switch position of on/ off linked to relays among other parts and elements.
3) Functions and Applications
4) BJ01: High Alarm Limit Switch (HA) BJ02:Low Alarm Limit Switch(LA), Both the switches of BJ02 are to send relevant signals at maximum, middle and minimum flow. The switches are mounted on certain selected position of rail and whenever magnetic flout reaches or passes the switch level, signals will be sent out for internal contact actuation of either opening or closing.
5) Technical Parameter
6) Rated Voltage: max DC24/AC24 Rated Amperage: max 0.3A Steady Current at Switches Opening or Closing: max DC 0.1A Interruption Capacity: ≤10W Insulation Impedance: > 10^9 Ω Working Temperature: 0℃-+55℃ Protection Grading: IP65 Displacement(position on or off): ≤4mm
7) Precautions
8) Keep off from ambient magnetic disturbance during mounting e.g. large motors etc;
9) Flow media should be free from ferromagnetic foreign matters;
10) Ensure pipes or tubes to be mounted with the flowmeters free from any potential vibration in case switch contact actuates accidentally.
■Datasheet of LZB Series Flowmeters with Alarm Limit Switches
Model |
LZB-40 |
LZB-50 |
LZB-80 |
LZB-100 |
LZB-100 |
|
Diameter(mm) |
Ф40 |
Ф50 |
Ф80 |
Ф100 |
Ф100 |
|
Range
|
l/h
|
160-1600 |
★160-1600 |
1-10m3/h |
5-25 |
★20-90 |
★180-1800 |
400-4000 |
1.6-16m3/h |
★6-35 |
★20-100 |
||
250-2500 |
600-6000 |
★2-20m3/h |
8-40 |
★30-100 |
||
★300-3000 |
★800-8000 |
★3-25 |
★12-60 |
★50-120 |
||
★400-4000 |
★1-10m3/h |
★8-40 |
★16-80 |
|
||
★1-5 |
★4-16m3/h |
|
|
|
||
★1.5-6m3/h |
|
|
|
|
||
N
|
4-40 |
★ 6-60 |
50-250 |
★60-200 |
★300-1500 |
|
★5-50 |
10-100 |
80-400 |
★80-400 |
★300-1600 |
||
6-60 |
16-160 |
★750-7500l/min |
★100-500 |
★400-2000 |
||
★7-70 |
★20-200 |
★6-60 |
120-600 |
★500-2500 |
||
★8-80 |
★30-300 |
|
200-1000 |
|
||
★10-100 |
★50-250 |
|
|
|
||
|
★80-400 |
|
|
|
||
Accuracy ±% |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
|
Working Pressure(MPa) |
≤0.6 |
≤0.6 |
≤0.4 |
≤0.4 |
≤0.4 |
Range with ★ represents customer tailored special range.
Clamp On Flow Meters primarily operate using ultrasonic technologies—either transit-time or Doppler ...
READ MOREThe Bourdon tube is the core functional element in the Bourdon Spring Pressure Gauge, and its abilit...
READ MOREExtreme temperature fluctuations can significantly affect the accuracy and longevity of a Bourdon Sp...
READ MOREThe 26th China Environmental Protection Expo 2025 Exhibition Time: 20225.4.21-23 Exhibition Location...
READ MOREAs a core component in the field of industrial automation and fluid control, the core working princi...
READ MORE